Description
In the Linux kernel, the following vulnerability has been resolved:
iommu/amd: Fix ineffective error check in nested domain allocation
amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the
negative errno from ida_alloc_range() when the ID space is exhausted or
memory is short. amd_iommu_alloc_domain_nested() stores that return value
in gdom_info->hdom_id, which is a u32, and only then tests it:
gdom_info->hdom_id = amd_iommu_pdom_id_alloc();
if (gdom_info->hdom_id <= 0) {
The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the
test never fires. The nested domain is then set up with a host domain ID
that was never allocated, instead of the allocation failing with -ENOSPC.
Keep the value in an int, test it there, and store it only once it is
known to be valid, which is what the other amd_iommu_pdom_id_alloc()
callers already do.
iommu/amd: Fix ineffective error check in nested domain allocation
amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the
negative errno from ida_alloc_range() when the ID space is exhausted or
memory is short. amd_iommu_alloc_domain_nested() stores that return value
in gdom_info->hdom_id, which is a u32, and only then tests it:
gdom_info->hdom_id = amd_iommu_pdom_id_alloc();
if (gdom_info->hdom_id <= 0) {
The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the
test never fires. The nested domain is then set up with a host domain ID
that was never allocated, instead of the allocation failing with -ENOSPC.
Keep the value in an int, test it there, and store it only once it is
known to be valid, which is what the other amd_iommu_pdom_id_alloc()
callers already do.
Published:
2026-09-25
Score:
n/a
EPSS:
n/a
KEV:
No
Analysis and contextual insights are available on OpenCVE Cloud.
Remediation
No vendor fix or workaround currently provided.
Additional remediation guidance may be available on OpenCVE Cloud.
Tracking
Sign in to view the affected projects.
Advisories
No advisories yet.
References
History
Fri, 25 Sep 2026 10:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | In the Linux kernel, the following vulnerability has been resolved: iommu/amd: Fix ineffective error check in nested domain allocation amd_iommu_pdom_id_alloc() returns an int: a domain ID on success, or the negative errno from ida_alloc_range() when the ID space is exhausted or memory is short. amd_iommu_alloc_domain_nested() stores that return value in gdom_info->hdom_id, which is a u32, and only then tests it: gdom_info->hdom_id = amd_iommu_pdom_id_alloc(); if (gdom_info->hdom_id <= 0) { The assignment discards the sign, so -ENOSPC becomes 0xffffffe4 and the test never fires. The nested domain is then set up with a host domain ID that was never allocated, instead of the allocation failing with -ENOSPC. Keep the value in an int, test it there, and store it only once it is known to be valid, which is what the other amd_iommu_pdom_id_alloc() callers already do. | |
| Title | iommu/amd: Fix ineffective error check in nested domain allocation | |
| First Time appeared |
Linux
Linux linux Kernel |
|
| CPEs | cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Linux
Linux linux Kernel |
|
| References |
|
Status: PUBLISHED
Assigner: Linux
Published:
Updated: 2026-09-25T10:23:29.929Z
Reserved: 2026-09-25T10:19:56.068Z
Link: CVE-2026-98002
No data.
Status : Received
Published: 2026-09-25T11:17:28.430
Modified: 2026-09-25T11:17:28.430
Link: CVE-2026-98002
No data.
OpenCVE Enrichment
No data.
Weaknesses
No weakness.