Export limit exceeded: 55466 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (55466 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-36583 | 1 Byondreal | 1 Accessor | 2026-04-15 | 8.1 High |
| A Prototype Pollution issue in byondreal accessor <= 1.0.0 allows an attacker to execute arbitrary code via @byondreal/accessor/index. | ||||
| CVE-2024-36582 | 1 Alykoshin | 1 Mini-deep-assign | 2026-04-15 | 9.8 Critical |
| alexbinary object-deep-assign 1.0.11 is vulnerable to Prototype Pollution via the extend() method of Module.deepAssign (/src/index.js) | ||||
| CVE-2023-5407 | 2026-04-15 | 5.9 Medium | ||
| Controller denial of service due to improper handling of a specially crafted message received by the controller. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
| CVE-2023-5404 | 2026-04-15 | 8.1 High | ||
| Server receiving a malformed message can cause a pointer to be overwritten which can result in a remote code execution or failure. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
| CVE-2023-5401 | 1 Honeywell | 1 Experion Server | 2026-04-15 | 8.1 High |
| Server receiving a malformed message based on a using the specified key values can cause a stack overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
| CVE-2023-5400 | 2026-04-15 | 8.1 High | ||
| Server receiving a malformed message based on a using the specified key values can cause a heap overflow vulnerability which could lead to an attacker performing remote code execution or causing a failure. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
| CVE-2023-5398 | 1 Honeywell | 1 Experion Server | 2026-04-15 | 5.9 Medium |
| Server receiving a malformed message based on a list of IPs resulting in heap corruption causing a denial of service. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
| CVE-2024-36578 | 1 Akbr | 1 Update | 2026-04-15 | 5.9 Medium |
| akbr update 1.0.0 is vulnerable to Prototype Pollution via update/index.js. | ||||
| CVE-2024-36577 | 1 Apphp | 1 Apphp Js-object-resolver | 2026-04-15 | 8.3 High |
| apphp js-object-resolver < 3.1.1 is vulnerable to Prototype Pollution via Module.setNestedProperty. | ||||
| CVE-2024-36574 | 1 Amirziai | 1 Flatten Json | 2026-04-15 | 6.3 Medium |
| A Prototype Pollution issue in flatten-json 1.0.1 allows an attacker to execute arbitrary code via module.exports.unflattenJSON (flatten-json/index.js:42) | ||||
| CVE-2024-36573 | 1 Almela | 1 Obx | 2026-04-15 | 9.8 Critical |
| almela obx before v.0.0.4 has a Prototype Pollution issue which allows arbitrary code execution via the obx/build/index.js:656), reduce (@almela/obx/build/index.js:470), Object.set (obx/build/index.js:269) component. | ||||
| CVE-2024-36580 | 2026-04-15 | 9.8 Critical | ||
| A Prototype Pollution issue in cdr0 sg 1.0.10 allows an attacker to execute arbitrary code. | ||||
| CVE-2024-36533 | 1 Volcano | 1 Volcano | 2026-04-15 | 9.8 Critical |
| Insecure permissions in volcano v1.8.2 allows attackers to access sensitive data and escalate privileges by obtaining the service account's token. | ||||
| CVE-2022-50238 | 1 Microsoft | 1 Windows | 2026-04-15 | 7.4 High |
| The on-endpoint Microsoft vulnerable driver blocklist is not fully synchronized with the online Microsoft recommended driver block rules. Some entries present on the online list have been excluded from the on-endpoint blocklist longer than the expected periodic monthly Windows updates. It is possible to fully synchronize the driver blocklist using WDAC policies. NOTE: The vendor explains that Windows Update provides a smaller, compatibility-focused driver blocklist for general users, while the full XML list is available for advanced users and organizations to customize at the risk of usability issues. | ||||
| CVE-2024-21505 | 2026-04-15 | 7.5 High | ||
| Versions of the package web3-utils before 4.2.1 are vulnerable to Prototype Pollution via the utility functions format and mergeDeep, due to insecure recursive merge. An attacker can manipulate an object's prototype, potentially leading to the alteration of the behavior of all objects inheriting from the affected prototype by passing specially crafted input to these functions. | ||||
| CVE-2025-52938 | 2026-04-15 | N/A | ||
| Out-of-bounds Read vulnerability in dail8859 NotepadNext (src/lua/src modules). This vulnerability is associated with program files lparser.C. This issue affects NotepadNext: through v0.11. The singlevar() in lparser.c lacks a certain luaK_exp2anyregup call, leading to a heap-based buffer over-read that might affect a system that compiles untrusted Lua code. | ||||
| CVE-2025-32014 | 2026-04-15 | N/A | ||
| estree-util-value-to-estree converts a JavaScript value to an ESTree expression. When generating an ESTree from a value with a property named __proto__, valueToEstree would generate an object that specifies a prototype instead. This vulnerability is fixed in 3.3.3. | ||||
| CVE-2025-32029 | 2026-04-15 | N/A | ||
| ts-asn1-der is a collection of utility classes to encode ASN.1 data following DER rule. Incorrect number DER encoding can lead to denial on service for absolute values in the range 2**31 -- 2**32 - 1. The arithmetic in the numBitLen didn't take into account that values in this range could result in a negative result upon applying the >> operator, leading to an infinite loop. The issue is patched in version 1.0.4. If upgrading is not an option, the issue can be mitigated by validating inputs to Asn1Integer to ensure that they are not smaller than -2**31 + 1 and no larger than 2**31 - 1. | ||||
| CVE-2023-5395 | 1 Honeywell | 1 Experion Server | 2026-04-15 | 8.1 High |
| Server receiving a malformed message that uses the hostname in an internal table may cause a stack overflow resulting in possible remote code execution. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||
| CVE-2023-5394 | 1 Honeywell | 1 Experion Server | 2026-04-15 | 7.4 High |
| Server receiving a malformed message that where the GCL message hostname may be too large which may cause a stack overflow; resulting in possible remote code execution. Honeywell recommends updating to the most recent version of the product. See Honeywell Security Notification for recommendations on upgrading and versioning. | ||||