Search Results (55490 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-43698 1 Kieback\&peter 10 Ddc4002 Firmware, Ddc4002e Firmware, Ddc4020e Firmware and 7 more 2026-04-15 9.8 Critical
Kieback & Peter's DDC4000 series uses weak credentials, which may allow an unauthenticated attacker to get full admin rights on the system.
CVE-2025-20101 1 Intel 1 Graphics Drivers 2026-04-15 8.4 High
Out-of-bounds read for some Intel(R) Graphics Drivers may allow an authenticated user to potentially enable information disclosure or denial of service via local access.
CVE-2024-9506 2026-04-15 3.7 Low
Improper regular expression in Vue's parseHTML function leads to a potential regular expression denial of service vulnerability.
CVE-2024-7316 2026-04-15 5.9 Medium
Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric CNC Series allows a remote unauthenticated attacker to cause Denial of Service (DoS) condition on the product by sending specially crafted packets to TCP port 683, causing an emergency stop.
CVE-2024-43661 2026-04-15 9.8 Critical
The <redacted>.so library, which is used by <redacted>, is vulnerable to a buffer overflow in the code that handles the deletion of certificates. This buffer overflow can be triggered by providing a long file path to the <redacted> action of the <redacted>.exe CGI binary or to the <redacted>.sh CGI script. This binary or script will write this file path to <redacted>, which is then read by <redacted>.so This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – An attacker will have to find this exploit by either obtaining the binaries involved in this vulnerability, or by trial and error. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe CGI binary or <redacted>.sh script to trigger the vulnerability, or convince a user with such access send an HTTP request that triggers it. Impact: High – The <redacted> process, which we assume is responsible for OCPP communication, will keep crashing after performing the exploit. This happens because the buffer overflow causes the process to segfault before <redacted> is removed. This means that, even though <redacted> is automatically restarted, it will crash again as soon as it tries to parse the text file. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack leads to reducred availability of the device (VC:N/VI:N/VA:H). THere is not impact on subsequent systems. (SC:N/SI:N/SA:N). Alltough this device is an EV charger handing significant amounts of power, we do not forsee a safety impact. The attack can be automated (AU:Y). Because the DoS condition is written to disk persistantly, it cannot be recovered by the user (R:I).
CVE-2024-57513 2026-04-15 6.5 Medium
A floating-point exception (FPE) vulnerability exists in the AP4_TfraAtom::AP4_TfraAtom function in Bento4.
CVE-2024-43659 2026-04-15 7.2 High
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2025-41726 1 Beckhoff 4 Beckhoff.device.manager.xar, Mdp Package, Twincat and 1 more 2026-04-15 8.8 High
A low privileged remote attacker can execute arbitrary code by sending specially crafted calls to the web service of the Device Manager or locally via an API and can cause integer overflows which then may lead to arbitrary code execution within privileged processes.
CVE-2024-57510 2026-04-15 7.8 High
Buffer Overflow vulnerability in Bento4 mp42avc v.3bdc891602d19789b8e8626e4a3e613a937b4d35 allows a local attacker to execute arbitrary code via the AP4_MemoryByteStream::WritePartial.
CVE-2024-57509 2026-04-15 7.8 High
Buffer Overflow vulnerability in Bento4 mp42avc v.3bdc891602d19789b8e8626e4a3e613a937b4d35 allows a local attacker to execute arbitrary code via the AP4_File::ParseStream and related functions.
CVE-2024-4760 1 Amtel 4 Same70, Sams70, Samv70 and 1 more 2026-04-15 6.3 Medium
A voltage glitch during the startup of EEFC NVM controllers on Microchip SAM E70/S70/V70/V71, SAM G55, SAM 4C/4S/4N/4E, and SAM 3S/3N/3U microcontrollers allows access to the memory bus via the debug interface even if the security bit is set.
CVE-2024-8938 1 Schneider-electric 3 Modicon M340, Modicon Mc80, Modicon Momentum Unity M1e Processor 2026-04-15 8.1 High
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a potential arbitrary code execution after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in memory size computation.
CVE-2024-8937 2026-04-15 6.5 Medium
CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a potential arbitrary code execution after a successful Man-In-The Middle attack followed by sending a crafted Modbus function call to tamper with memory area involved in the authentication process.
CVE-2024-48289 2026-04-15 6.5 Medium
An issue in the Bluetooth Low Energy implementation of Cypress Bluetooth SDK v3.66 allows attackers to cause a Denial of Service (DoS) via supplying a crafted LL_PAUSE_ENC_REQ packet.
CVE-2024-46461 1 Videolan 1 Vlc Media Player 2026-04-15 8 High
VLC media player 3.0.20 and earlier is vulnerable to denial of service through an integer overflow which could be triggered with a maliciously crafted mms stream (heap based overflow). If successful, a malicious third party could trigger either a crash of VLC or an arbitrary code execution with the target user's privileges.
CVE-2024-46483 1 Xlightftpd 1 Xlight Ftp Server 2026-04-15 9.8 Critical
Xlight FTP Server <3.9.4.3 has an integer overflow vulnerability in the packet parsing logic of the SFTP server, which can lead to a heap overflow with attacker-controlled content.
CVE-2025-1836 2026-04-15 4.3 Medium
A vulnerability was found in Incorta 2023.4.3. It has been classified as problematic. Affected is an unknown function of the component Edit Insight Handler. The manipulation of the argument Service Name leads to csv injection. It is possible to launch the attack remotely. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-12143 1 Abb 1 Terra Ac Wallbox Jp 2026-04-15 6.1 Medium
Stack-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33.
CVE-2024-46547 2026-04-15 7.5 High
A vulnerability was found in Romain Bourdon Wampserver all versions (discovered in v3.2.3 and v3.2.6) where unauthorized users could access sensitive information due to improper access control validation via PHP Info Page. This issue can lead to data leaks.
CVE-2024-48290 1 Realtek 1 Rtl8762ekf-evb Firmware 2026-04-15 4.3 Medium
An issue in the Bluetooth Low Energy implementation of Realtek RTL8762E BLE SDK v1.4.0 allows attackers to cause a Denial of Service (DoS) via supplying a crafted ll_terminate_ind packet.