Search Results (110436 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-96264 1 Ibm 1 Powervm Hypervisor 2026-10-13 8.2 High
IBM Power Systems Firmware FW1060.00 through FW1060.81 is affected by a vulnerability in the service processor mailbox interface. An attacker with authenticated service-level access to the FSP can send a specially crafted mailbox message to overflow host firmware runtime attribute storage, allowing arbitrary code to be executed in the host firmware runtime. This gives the attacker full access to the managed system's memory and hardware interfaces, resulting in a confidentiality, integrity, and availability impact to the managed system.
CVE-2026-96263 1 Ibm 1 Powervm Hypervisor 2026-10-13 8.2 High
IBM Power Systems Firmware FW1120.00 through FW1120.01, FW1110.00 through FW1110.31, and FW1060.00 through FW1060.81 is affected by a vulnerability in the host firmware boot process image validation path. An attacker with service access to the service processor can supply a maliciously crafted code update image, allowing arbitrary code to be executed on the host system. Successful exploitation could result in a confidentiality, integrity, and availability impact to the affected host system.
CVE-2026-96262 1 Ibm 1 Powervm Hypervisor 2026-10-13 8.2 High
IBM Power Systems Firmware FW1060.00 through FW1060.81 is affected by a vulnerability in the service processor mailbox interface. An attacker with authenticated service-level access to the FSP can send a specially crafted mailbox message to overflow host firmware runtime attribute storage, allowing arbitrary code to be executed in the host firmware runtime. This gives the attacker full access to the managed system's memory and hardware interfaces, resulting in a confidentiality, integrity, and availability impact to the managed system.
CVE-2026-12780 1 Aomei 1 Backupper 2026-10-13 7.8 High
A vulnerability was determined in AOMEI Backupper up to 8.3.0. Impacted is an unknown function in the library amwrtdrv.sys of the component Kernel Driver. Executing a manipulation can lead to improper access controls. The attack needs to be launched locally. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2026-108549 1 Chenhg5 1 Cc-connect 2026-10-13 8.1 High
cc-connect through 1.5.0 contains a missing authentication vulnerability in the MAX platform adapter webhook mode in platform/max/max.go that accepts unauthenticated updates when no webhook_secret is configured. Remote attackers reaching the webhook listener on port 8080 can forge updates with an allowed or admin user_id to run privileged commands like /shell on the host.
CVE-2026-105465 1 Ibm 1 Db2 2026-10-13 8.8 High
IBM Db2 11.5.0 through 11.5.9, and 12.1.0 through 12.1.5 is vulnerable to privilege escalation when db2locssh is enabled with the db2 instance.
CVE-2026-105464 1 Ibm 1 Db2 2026-10-13 8.8 High
IBM Db2 11.5.0 through 11.5.9, and 12.1.0 through 12.1.5 for Linux, UNIX and Windows (includes DB2 Connect Server) could allow a local attacker to gain elevated privileges due to improper privilege management.
CVE-2026-103903 1 Mikrotik 1 Routeros 2026-10-13 8.8 High
An incorrect authorization vulnerability in the WinBox authentication flow of MikroTik RouterOS allows a remote authenticated attacker with credentials for a low-privilege account permitted to use WinBox to obtain the authorization policy of a different existing account. The stage-one EC-SRP challenge and proof are verified using the attacker's account, while the independently supplied stage-two username is used to install the target account's privileges. By specifying a higher-privilege account such as admin, a low-privilege user can obtain a full administrative session without knowing the target account's password and can use that session to increase the privileges of the attacker's own account.
CVE-2026-102117 2 Accellion, Kiteworks 2 Kiteworks, Core 2026-10-13 7.2 High
On deployments where the remote-support capability is licensed and enabled, an authenticated System Administrator who also possessed the key protecting the submitted data could redirect the underlying system's outbound support connection to a destination of their choosing. That destination could then have operating-system commands executed on the node and receive their output, potentially resulting in remote code execution with the privileges of a local service account.
CVE-2026-102119 2 Accellion, Kiteworks 2 Kiteworks, Kiteworks Email Protection Gateway 2026-10-13 7.2 High
A path traversal weakness in an optional, non-default administrative feature allowed an authenticated administrator to move files to unintended locations outside the feature's designated directory. This could potentially be leveraged to execute arbitrary code on the underlying system.
CVE-2026-102143 2 Accellion, Kiteworks 2 Kiteworks, Kiteworks Email Protection Gateway 2026-10-13 7.5 High
An unauthenticated attacker could cause a file with attacker-controlled content to be written to the appliance filesystem through an administrative upload handler that did not properly authenticate the request. This did not by itself result in code execution, which would require a separate vulnerability to place the file in an executable location.
CVE-2025-40946 1 Siemens 30 Blueplanet 100 Nx3 M8, Blueplanet 100 Tl3 Gen2, Blueplanet 105 Tl3 and 27 more 2026-10-13 8.3 High
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 3.0 TL3-60.0 TL3 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet gridsave 110 TL3-S (All versions < V3.91), blueplanet gridsave 137 TL3-S (All versions < V3.91), blueplanet gridsave 92.0 TL3-S (All versions < V3.91). A CRC16-based algorithm for generating Technical Service credentials could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access.
CVE-2025-40816 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 7.6 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
CVE-2025-40815 1 Siemens 2 Logo!, Siplus Logo! 2026-10-13 7.2 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
CVE-2024-52051 2026-10-13 7.3 High
A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC S7-PLCSIM V18 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified PC Runtime V18 (All versions), SIMATIC WinCC Unified PC Runtime V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions), TIA Portal Cloud V18 (All versions), TIA Portal Cloud V19 (All versions < V5.2.1.1). The affected devices do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to locally execute arbitrary commands in the host operating system with the privileges of the user.
CVE-2026-108865 1 Amoylab 1 Unla 2026-10-13 8.2 High
AmoyLab Unla through 0.10.0 contains an authentication bypass vulnerability that allows unauthenticated attackers to obtain valid access tokens because the OAuth2 server never authenticates a resource owner. Attackers can register a client, request a code from /authorize, and exchange it at /token to access OAuth2-protected MCP prefixes, proxied upstream APIs and injected credentials.
CVE-2026-103521 1 Thelia 1 Thelia 2026-10-13 7.2 High
In Thelia v2.6.0, the document upload endpoint properly blocks the upload of executable file types, but the document update endpoint does not perform the same validation. An attacker with administrative Thelia permissions can exploit this vulnerability to upload arbitrary executable files, such as malicious PHP scripts, to achieve remote code execution on the underlying server.
CVE-2026-103522 1 Thelia 1 Thelia 2026-10-13 7.2 High
In Thelia v2.6.0, the store banner upload feature performs insufficient filetype validation that relies exclusively on client‑supplied MIME types. An attacker with administrative access can upload a PHP file disguised as an image to bypass validation and achieve remote code execution on the underlying server.
CVE-2026-42697 2026-10-13 7.1 High
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Inisev Social Share Icons & Social Share Buttons ultimate-social-media-plus allows Reflected XSS.This issue affects Social Share Icons & Social Share Buttons: from n/a through 3.7.5.
CVE-2024-12085 8 Almalinux, Archlinux, Gentoo and 5 more 29 Almalinux, Arch Linux, Linux and 26 more 2026-10-13 7.5 High
A flaw was found in rsync which could be triggered when rsync compares file checksums. This flaw allows an attacker to manipulate the checksum length (s2length) to cause a comparison between a checksum and uninitialized memory and leak one byte of uninitialized stack data at a time.