| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/run/storage_account_root permissions. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/etc/hnapasswd permissions. |
| D-Link DIR-850L REV. A (with firmware through FW114WWb07_h2ab_beta1) and REV. B (with firmware through FW208WWb02) devices have 0666 /var/passwd permissions. |
| Huawei VMall (for Android) with the versions before 1.5.8.5 have a privilege elevation vulnerability due to improper design. An attacker can trick users into installing a malicious app which can send out HTTP requests and execute JavaScript code in web pages without obtaining the Internet access permission. Successful exploit could lead to resource occupation or information leak. |
| Elastic X-Pack Security versions prior to 5.4.1 and 5.3.3 did not always correctly apply Document Level Security to index aliases. This bug could allow a user with restricted permissions to view data they should not have access to when performing certain operations against an index alias. |
| In Flatpak before 0.8.7, a third-party app repository could include malicious apps that contain files with inappropriate permissions, for example setuid or world-writable. The files are deployed with those permissions, which would let a local attacker run the setuid executable or write to the world-writable location. In the case of the "system helper" component, files deployed as part of the app are owned by root, so in the worst case they could be setuid root. |
| Polycom BToE Connector before 3.0.0 uses weak permissions (Everyone: Full Control) for "Program Files (x86)\polycom\polycom btoe connector\plcmbtoesrv.exe," which allows local users to gain privileges via a Trojan horse file. |
| Parameterized Trigger Plugin fails to check Item/Build permission: The Parameterized Trigger Plugin did not check the build authentication it was running as and allowed triggering any other project in Jenkins. |
| In Ivanti Service Desk (formerly LANDESK Management Suite) versions between 2016.3 and 2017.3, an Unrestricted Direct Object Reference leads to referencing/updating objects belonging to other users. In other words, a normal user can send requests to a specific URI with the target user's username in an HTTP payload in order to retrieve a key/token and use it to access/update objects belonging to other users. Such objects could be user profiles, tickets, incidents, etc. |
| The XML-RPC server in supervisor before 3.0.1, 3.1.x before 3.1.4, 3.2.x before 3.2.4, and 3.3.x before 3.3.3 allows remote authenticated users to execute arbitrary commands via a crafted XML-RPC request, related to nested supervisord namespace lookups. |
| AlienVault USM and OSSIM before 5.3.7 and NfSen before 1.3.8 have an error in privilege dropping and unnecessarily execute the NfSen Perl code as root, aka AlienVault ID ENG-104945, a different vulnerability than CVE-2017-6970 and CVE-2017-6971. |
| An issue was discovered in certain Apple products. iOS before 11 is affected. The issue involves the "Time" component. The "Setting Time Zone" feature mishandles the possibility of using location data. |
| An issue was discovered in Logpoint 7.1 before 7.1.2. The daily executed cron file clean_secbi_old_logs is writable by all users and is executed as root, leading to privilege escalation. |
| Sourcecodester Human Resource Management System 1.0 is vulnerable to Insecure Permissions resulting in privilege escalation. |
| Insecure permission vulnerability in /hrm/leaverequest.php in SourceCodester Human Resource Management System 1.0 allow attackers to approve or reject leave ticket. |
| Sysmac Studio installs executables in a directory with poor permissions. This can allow a locally-authenticated attacker to overwrite files which will result in code execution with privileges of a different user. |
| Apiman 1.5.7 through 2.2.3.Final has insufficient checks for read permissions within the Apiman Manager REST API. The root cause of the issue is the Apiman project's accidental acceptance of a large contribution that was not fully compatible with the security model of Apiman versions before 3.0.0.Final. Because of this, 3.0.0.Final is not affected by the vulnerability. |
| Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to an incorrect default permission in the DIAEnergie application, which may allow an attacker to plant new files (such as DLLs) or replace existing executable files. |
| Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. |