| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Cleartext Storage of Sensitive Information (CWE-312) in the Gallagher Morpho integration could allow an authenticated user with access to the Command Centre Server to export a specific signing key while in use allowing them to deploy a compromised or counterfeit device on that site.
This issue affects Command Centre Server: 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior. |
| A sensitive information disclosure vulnerability in Palo Alto Networks Prisma® Browser allows a locally authenticated non-admin user to retrieve sensitive data from Prisma Browser.
Browser self-protection should be enabled to mitigate this issue. |
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| Arctera/Veritas Data Insight before 7.1.2 can send cleartext credentials when configured to use HTTP Basic Authentication to a Dell Isilon OneFS server. |
| The Pixmeo Osirix MD Web Portal sends credential information without encryption, which could allow an attacker to steal credentials. |
| Cleartext transmission of sensitive information issue exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a man-in-the-middle attack may allow a remote unauthenticated attacker to eavesdrop the communication and obtain the authentication information. |
| The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack. |
| Lack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure. |
| Improper data protection on the ventilator's serial interface could allow an attacker to send and receive messages that result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| A flaw was found in Event-Driven Automation (EDA) in Ansible Automation Platform (AAP), which lacks encryption of sensitive information. An attacker with network access could exploit this vulnerability by sniffing the plaintext data transmitted between the EDA and AAP. An attacker with system access could exploit this vulnerability by reading the plaintext data stored in EDA and AAP databases. |
| A vulnerability in the IPS Manager, Central Manager, and Local Manager communication workflow allows an attacker to control the destination of a request by manipulating the parameter, thereby leveraging sensitive information. |
| Oxide before 6 has unencrypted Control Plane datastores. |
| zhmcclient is a pure Python client library for the IBM Z HMC Web Services API. In affected versions the Python package "zhmcclient" writes password-like properties in clear text into its HMC and API logs in the following cases: 1. The 'boot-ftp-password' and 'ssc-master-pw' properties when creating or updating a partition in DPM mode, in the zhmcclient API and HMC logs. 2. The 'ssc-master-pw' and 'zaware-master-pw' properties when updating an LPAR in classic mode, in the zhmcclient API and HMC logs. 3. The 'ssc-master-pw' and 'zaware-master-pw' properties when creating or updating an image activation profile in classic mode, in the zhmcclient API and HMC logs. 4. The 'password' property when creating or updating an HMC user, in the zhmcclient API log. 5. The 'bind-password' property when creating or updating an LDAP server definition, in the zhmcclient API and HMC logs. This issue affects only users of the zhmcclient package that have enabled the Python loggers named "zhmcclient.api" (for the API log) or "zhmcclient.hmc" (for the HMC log) and that use the functions listed above. This issue has been fixed in zhmcclient version 1.18.1. Users are advised to upgrade. There are no known workarounds for this vulnerability. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device. |
| ispdbservice.cpp in KDE Kmail before 6.2.0 allows man-in-the-middle attackers to trigger use of an attacker-controlled mail server because cleartext HTTP is used for a URL such as http://autoconfig.example.com or http://example.com/.well-known/autoconfig for retrieving the configuration. This is related to kmail-account-wizard. |
| Webservice API endpoints for Assisted Service Module within SAP Commerce Cloud has information disclosure vulnerability. When an authorized agent searches for customer to manage their accounts, the request url includes customer data and it is recorded in server logs. If an attacker impersonating as authorized admin visits such server logs, then they get access to the customer data. The amount of leaked confidential data however is extremely limited, and the attacker has no control over what data is leaked. |
| Sensitive data could be exposed to non- privileged users in a configuration file. Local access to the computer with a low- privileged account is required to access the configuration file containing the sensitive data. |
| A local, low-privileged attacker can learn the password of the connected controller in PLC Designer V4 due to an incorrect implementation that results in the password being displayed in plain text under special conditions. |
| A security issue was discovered within the legacy Ansible playbook component of Verve Asset Manager, caused by plaintext secrets incorrectly stored when a playbook is running. This component has been retired and has been optional since the 1.36 release in 2024. |
| Under certain circumstances, attacker can capture the network key, read or write encrypted packets on the PowerG network. |