Export limit exceeded: 396005 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (4720 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-8689 2026-04-15 N/A
A problem with the ActiveMQ integration for both Cortex XSOAR and Cortex XSIAM can result in the cleartext exposure of the configured ActiveMQ credentials in log bundles.
CVE-2024-9620 1 Redhat 1 Ansible Automation Platform 2026-04-15 5.3 Medium
A flaw was found in Event-Driven Automation (EDA) in Ansible Automation Platform (AAP), which lacks encryption of sensitive information. An attacker with network access could exploit this vulnerability by sniffing the plaintext data transmitted between the EDA and AAP. An attacker with system access could exploit this vulnerability by reading the plaintext data stored in EDA and AAP databases.
CVE-2024-47789 1 D3dsecurity 1 D8801 2026-04-15 N/A
** UNSUPPORTED WHEN ASSIGNED ** This vulnerability exists in D3D Security IP Camera D8801 due to usage of weak authentication scheme of the HTTP header protocol where authorization tag contain a Base-64 encoded username and password. A remote attacker could exploit this vulnerability by crafting a HTTP packet leading to exposure of user credentials of the targeted device. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-48428 1 Gallagher 1 Command Centre 2026-04-15 6.7 Medium
Cleartext Storage of Sensitive Information (CWE-312) in the Gallagher Morpho integration could allow an authenticated user with access to the Command Centre Server to export a specific signing key while in use allowing them to deploy a compromised or counterfeit device on that site. This issue affects Command Centre Server: 9.20 prior to vEL9.20.2819 (MR4), 9.10 prior to vEL9.10.3672 (MR7), 9.00 prior to vEL9.00.3831 (MR8), all versions of 8.90 and prior.
CVE-2025-7738 1 Redhat 2 Ansible Automation Platform, Ansible Automation Platform Developer 2026-04-15 4.4 Medium
A flaw was found in Ansible Automation Platform (AAP) where the Gateway API returns the client secret for certain GitHub Enterprise authenticators in clear text. This vulnerability affects administrators or auditors accessing authenticator configurations. While access is limited to privileged users, the clear text exposure of sensitive credentials increases the risk of accidental leaks or misuse.
CVE-2024-5731 2026-04-15 6.8 Medium
A vulnerability in the IPS Manager, Central Manager, and Local Manager communication workflow allows an attacker to control the destination of a request by manipulating the parameter, thereby leveraging sensitive information.
CVE-2023-28912 2026-04-15 5.7 Medium
The MIB3 unit stores the synchronized phone contact book in clear-text, allowing an attacker with either code execution privilege on the system or physical access to the system to obtain vehicle owner's contact data. The vulnerability was originally discovered in Skoda Superb III car with MIB3 infotainment unit OEM part number 3V0035820. The list of affected MIB3 OEM part numbers is provided in the referenced resources.
CVE-2025-7731 1 Mitsubishi Electric 1 Melsec Iq-f Series 2026-04-15 7.5 High
Cleartext Transmission of Sensitive Information vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU module allows a remote unauthenticated attacker to obtain credential information by intercepting SLMP communication messages, and read or write the device values of the product and stop the operations of programs by using the obtained credential information.
CVE-2025-7215 1 Fnkvision 1 Fnk-gu2 2026-04-15 1.6 Low
A vulnerability, which was classified as problematic, has been found in FNKvision FNK-GU2 up to 40.1.7. Affected by this issue is some unknown functionality of the file /rom/wpa_supplicant.conf. The manipulation leads to cleartext storage of sensitive information. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2024-53651 2026-04-15 4.6 Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device.
CVE-2024-55582 2026-04-15 5.7 Medium
Oxide before 6 has unencrypted Control Plane datastores.
CVE-2025-7214 1 Fnkvision 1 Fnk-gu2 2026-04-15 1.6 Low
A vulnerability classified as problematic was found in FNKvision FNK-GU2 up to 40.1.7. Affected by this vulnerability is an unknown functionality of the file /etc/shadow of the component MD5. The manipulation leads to risky cryptographic algorithm. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2025-6748 2026-04-15 2.1 Low
A vulnerability classified as problematic has been found in Bharti Airtel Thanks App 4.105.4 on Android. Affected is an unknown function of the file /Android/data/com.myairtelapp/files/. The manipulation leads to cleartext storage in a file or on disk. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-52586 1 Eg4 Electronics 7 Eg4 12000xp, Eg4 12kpv, Eg4 18kpv and 4 more 2026-04-15 6.9 Medium
The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.
CVE-2025-64305 2026-04-15 6.5 Medium
MicroServer copies parts of the system firmware to an unencrypted external SD card on boot, which contains user and vendor secrets. An attacker can utilize these plaintext secrets to modify the vendor firmware, or gain admin access to the web portal.
CVE-2025-2182 1 Palo Alto Networks 1 Pan-os 2026-04-15 N/A
A problem with the implementation of the MACsec protocol in Palo Alto Networks PAN-OS® results in the cleartext exposure of the connectivity association key (CAK). This issue is only applicable to PA-7500 Series devices which are in an NGFW cluster. A user who possesses this key can read messages being sent between devices in a NGFW Cluster. There is no impact in non-clustered firewalls or clusters of firewalls that do not enable MACsec.
CVE-2025-64389 1 Circutor 1 Tcprs1plus 2026-04-15 N/A
The web server of the device performs exchanges of sensitive information in clear text through an insecure protocol.
CVE-2024-28275 1 Puwellcloudtech 1 360eyes Pro 2026-04-15 6.5 Medium
Puwell Cloud Tech Co, Ltd 360Eyes Pro v3.9.5.16(3090516) was discovered to transmit sensitive information in cleartext. This vulnerability allows attackers to intercept and access sensitive information, including users' credentials and password change requests.
CVE-2025-27594 2026-04-15 7.5 High
The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack.
CVE-2025-4394 2026-04-15 6.8 Medium
Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025