| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An unauthenticated attacker who can connect to the Web Services feature (HTTP TCP port 80) can issue a WS-Scan SOAP request containing an unexpected JobToken value which will crash the target device. The device will reboot, after which the attacker can reissue the command to repeatedly crash the device. |
| An unauthenticated attacker who can connect to TCP port 9100 can issue a Printer Job Language (PJL) command that will crash the target device. The device will reboot, after which the attacker can reissue the command to repeatedly crash the device. A malformed PJL variable FORMLINES is set to a non number value causing the target to crash. |
| editorconfig-core-c is theEditorConfig core library written in C (for use by plugins supporting EditorConfig parsing). In affected versions several overflows may occur in switch case '[' when the input pattern contains many escaped characters. The added backslashes leave too little space in the output pattern when processing nested brackets such that the remaining input length exceeds the output capacity. This issue has been addressed in release version 0.12.7. Users are advised to upgrade. There are no known workarounds for this vulnerability. |
| rPGP is a pure Rust implementation of OpenPGP. Prior to 0.14.1, rPGP allows an attacker to trigger rpgp crashes by providing crafted data. This vulnerability is fixed in 0.14.1. |
| An unauthenticated remote attacker can exploit input validation in cmd services of the devices, allowing them to disrupt system operations and potentially cause a denial-of-service. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |
| RedisBloom adds a set of probabilistic data structures to Redis. There is an integer overflow vulnerability in RedisBloom, which is a module used in Redis. The integer overflow vulnerability allows an attacker (a redis client which knows the password) to allocate memory in the heap lesser than the required memory due to wraparound. Then read and write can be performed beyond this allocated memory, leading to info leak and OOB write. The integer overflow is in CMS.INITBYDIM command, which initialize a Count-Min Sketch to dimensions specified by user. It accepts two values (width and depth) and uses them to allocate memory in NewCMSketch(). This vulnerability is fixed in 2.2.19, 2.4.12, 2.6.14, and 2.8.2. |
| A stack-based buffer overflow vulnerability due to a missing bounds check in the NI I/O Trace Tool may result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted nitrace file.
The NI I/O Trace tool is installed as part of the NI System Configuration utilities included with many NI software products. Refer to the NI Security Advisory for identifying the version of NI IO Trace.exe installed. The NI I/O Trace tool was also previously released as NI Spy. |
| Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password.
A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged. |
| 51l3nc3, member of the AXIS OS Bug Bounty Program, has found that the VAPIX API managedoverlayimages.cgi was vulnerable to a race condition attack allowing for an attacker to block access to the overlay configuration page in the web interface of the Axis device. This flaw can only be exploited after authenticating with an operator- or administrator-privileged service account. Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution. |
| A security flaw has been discovered in mixmark-io turndown up to 7.2.1. This affects an unknown function of the file src/commonmark-rules.js. Performing manipulation results in inefficient regular expression complexity. It is possible to initiate the attack remotely. The exploit has been released to the public and may be exploited. |
| Out-Of-Bounds Read vulnerability exists in the JT file reading procedure in SOLIDWORKS eDrawings on Release SOLIDWORKS Desktop 2025. This vulnerability could allow an attacker to execute arbitrary code while opening a specially crafted JT file. |
| A malicious client acting as the receiver of an rsync file transfer can trigger an out of bounds read of a heap based buffer, via a negative array index. The
malicious
rsync client requires at least read access to the remote rsync module in order to trigger the issue. |
| An integer underflow vulnerability in the Silicon Labs Z-Wave Protocol Controller can lead to out of bounds memory reads. |
| A security issue exists within DataMosaix™ Private Cloud, allowing attackers to bypass MFA during setup and obtain a valid login-token cookie without knowing the users password. This vulnerability occurs when MFA is enabled but not completed within a 7-day period. |
| CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an
attacker to execute unauthorized commands when a system’s default password credentials have not been
changed on first use. The default username is not displayed correctly in the WebHMI interface. |
| ArcSearch for iOS versions prior to 1.45.2 could display a different domain in the address bar than the content being shown after an iframe-triggered URI-scheme navigation, increasing spoofing risk. |
| A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user. |
| A credential management flaw in Palo Alto Networks Cortex XDR® Broker VM causes different Broker VM images to share identical default credentials for internal services. Users knowing these default credentials could access internal services on other Broker VM installations.
The attacker must have network access to the Broker VM to exploit this issue. |
| A heap buffer overflow vulnerability in FFmpeg before commit 4bf784c allows attackers to trigger a memory corruption via supplying a crafted media file in avformat when processing tile grid group streams. This can lead to a Denial of Service (DoS). |